The top part of the MTU can be removed to replace the termination board even with the system running. Such a need can be caused by a damaged terminal screw.The MTUs are available in tree versions (Compact, Extended and Redundant).The Compact MTU version typically provides for a compact installation of the I/O modules using 1 wire connections.The Extended MTU version provides for a more complete installation on the MTU,including 3 wire connection, fuses and field circuit power distribution. See Figure 3 and Figure 4 for an illustration of the MTUs together with the I/O modules.The Redundant MTUs are used in redundant I/O applications. There is space on the MTU for two I/O modules on separate ModuleBuses. See Figure 5.
TU842 Redundant Horizontal MTU for 50 V Applications
The TU842 is a 16 channel redundant module termination unit. The TU842 has
three rows of terminals for field signals and process power connection.It is intended
for mounting on a horizontal DIN rail. There is space on the MTU for two I/O
modules connected to separate ModuleBuses.
TU843 Redundant Vertical MTU for 50 V Applications
The TU843 is a 16 channel redundant module termination unit. The TU843 has
three rows of terminals for field signals and process power connection. It is intended
for mounting on a vertical DIN rail. There is space on the MTU for two I/O modules
connected to separate ModuleBuses.
TU844 Redundant Horizontal MTU for 50 V Applications
The TU844 is a 8 channel redundant module termination unit. The TU844 has two
rows of terminals for field signals and process power connection. It is a intended for
mounting on a horizontal DIN rail. The MTU has place for 8 replaceable shunt
sticks (i.e one shunt stick per channel) for conversion of the input current signal to a
voltage signal. There is space on the MTU for two I/O modules connected to
separate ModuleBuses.
TU845 Redundant Vertical MTU for 50 V Applications
The TU845 is a 8 channel redundant module termination unit. The TU845 has three
rows of terminals for field signals and process power connection. It is intended for
mounting on a vertical DIN rail. The MTU has place for 8 replaceable shunt sticks
(i.e one shunt stick per channel) for conversion of the input current signal to a
voltage signal. There is space on the MTU for two I/O modules connected to
separate ModuleBuses.
TU850 Extended MTU, Individually Current Limited and Disconnectable per
Channel for 50 V Applications
The TU850 is a 16 channel extended module termination unit. TU850 has two rows
of terminals for field signals and process power connection. Each channel has one
current limited sensor/transmitter power outlet terminal and one signal terminal.
Process voltage can be connected to two individually isolated groups.