Intrinsic safety barriers Temperature Converter HiD2082
- Product Model:HiD2082
- Country of origin:Singapore
- Delivery time:1 week
- Weight:140 g
- Product Description: Features: Sensor breakage detection, Configurable by PACTware, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508/IEC 6151.
Product introduction
Pepperl+Fuchs Intrinsic safety barriers Temperature Converter HiD2082.

Features
· 2-channel isolated barrier
· 24 V DC supply (bus powered)
· Thermocouple, RTD or potentiometer input
· Usable as signal splitter (1 input and 2 outputs)
· Linearized output 4 mA ... 20 mA, sink/source or 1 V ... 5 V
· Sensor breakage detection
· Configurable by PACTware
· Line fault detection (LFD)
· Up to SIL 2 acc. to IEC 61508/IEC 6151
Function: HiD2082
· This isolated barrier is used for intrinsic safety applications.
· This device accepts thermocouples (TC), millivolts, potentiometers, or resistance temperature detectors (RTD) from a hazardous area and converts them to an isolated, linearized analog output in the safe area.
· The outputs can be selected as a current source, current sink, or voltage source with DIP switches on the side panel.
· The device can also be configured as a signal splitter.
· Line fault detection of the field circuit is indicated by a red LED and an output on the fault bus. The fault conditions are monitored via a Fault Indication Board.
· The device is easily configured by the use of the PACTware configuration software.
· This device mounts on a HiD Termination Board.

Features
· 2-channel isolated barrier
· 24 V DC supply (bus powered)
· Thermocouple, RTD or potentiometer input
· Usable as signal splitter (1 input and 2 outputs)
· Linearized output 4 mA ... 20 mA, sink/source or 1 V ... 5 V
· Sensor breakage detection
· Configurable by PACTware
· Line fault detection (LFD)
· Up to SIL 2 acc. to IEC 61508/IEC 6151
Function: HiD2082
· This isolated barrier is used for intrinsic safety applications.
· This device accepts thermocouples (TC), millivolts, potentiometers, or resistance temperature detectors (RTD) from a hazardous area and converts them to an isolated, linearized analog output in the safe area.
· The outputs can be selected as a current source, current sink, or voltage source with DIP switches on the side panel.
· The device can also be configured as a signal splitter.
· Line fault detection of the field circuit is indicated by a red LED and an output on the fault bus. The fault conditions are monitored via a Fault Indication Board.
· The device is easily configured by the use of the PACTware configuration software.
· This device mounts on a HiD Termination Board.
We have good price on Pepperl+Fuchs Intrinsic safety barriers Temperature Converter HiD2082. We just ordered large quantity as our stock. If you have any interest on it, pls feel free to contact me.