CATEGORIES
Latest news
- ABB DCS ABB AC 800M ABB CI865 DCS
- ABB DCS ABB AC 800M ABB CI860 DCS
- ABB DCS ABB AC 800M ABB CI857 DCS
- ABB DCS ABB AC 800M ABB CI856 DCS
- ABB DCSABB AC 800M ABB CI853 DCS
Contact us
- ADD: UNIT A1.9/F SILVERCORP INTERNATIONAL TOWER707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG;
- TEL: 86-027-85508558,86-15871691193
- FAX: 86 027-85309780
- E-mail: sales1@hkxytech.com Jackie@hkxytech.com manager@field-instrument.com
Pepperl+Fuchs Fieldbus Terminator FP-FT-EX1.I.IEC
- Product Model:FP-FT-EX1.I.IEC
- Country of origin:Sinapore
- Delivery time:6-8 weeks
- Weight:0.5kG
- Product Description: We have good source to supply Pepperl fuchs isolated barrier.If you have any inquiry replate to our scope,pls feel free to contact me
Product introduction
Pepperl+Fuchs Fieldbus Terminator FP-FT-EX1.I.IEC
Pepperl+Fuchs Fieldbus Terminator FP-FT-EX1.I.IEC
Fieldbus Terminator FP-FT-EX1.I.IEC
Features
• Terminator in stainless steel housing
• Flameproof enclosure (Ex d) protection
• Installation on open cable gland
• Choice of threads 20 mm, Pg 13.5 mm or 1/2" NPT
• For FOUNDATION Fieldbus H1 and PROFIBUS PA
Function
FP-FT-EX1.I.IEC are terminators for fieldbus and provide capacitance and resistance to terminate a segment according to IEC/EN 61158-2. Explosion protection is flameproof enclosure 'Ex d' for installation in Zone 1 … 2. A solid metal housing enables installation in rough environments. Housings are selectable with 20 mm ISO, 13.5 mm PG, or 0.5 in NPT threads for easy installation on outdoor fieldbus junction boxes or field devices.
For increased availability, the terminator features multiple capacitors and resistors in a network. If one capacitor fails, the basic functionality remains intact. This is detectable with the FieldConnex® advanced diagnostic module, allowing timely maintenance. Pepperl+Fuchs Fieldbus Terminator FP-FT-EX1.I.IEC
Terminators are required at each end of the trunk line. They eliminate signal reflections at the end of the cable and convert the fieldbus signal transmitted as a current into a voltage, which is detectable by all devices. Pepperl+Fuchs Fieldbus Terminator FP-FT-EX1.I.IEC
Detailed Models
FD0-VC-EX4.FF
FS-FT-EX1.I.IEC
HID2026
FS-GIPFSDI-1624
KFA6-SR2-EX1-W
HIC2025
HIC2821
HD2-DM-B
HD2-FBPS-1.25.360
MBHD-FB-4R-YO
HD2-DM-B
HD2-FBPS-1.25.360
MBHD-FB-4R-YO
HIC2031
MBHD-FB1-4R-YO
HD2-FBPS-1.25.360
HD2-DM-B
HD2-DM-B
HD2-FBPS-1.500
HID 2026
HID 2030
HID 2038
F2D0-FB-EX4-FF-CGAB-CGAB
6XM20 F2D0-FB-EX4-M20
HD2-FBCL-1.500
HD2-DM-B
NCB10-30GM40-NO
NJ1.5-8N-Y18812
F2D0-FB-EX4.M20
F2D0-TI-EX-8-FF-CGB-ST
RD0-FB-Ex4
KFD0-CS-EX2.50P
KFD0-CS-EX2.51P
HD2-FBPS-1.500
HD2-DM-B
KFD0-CS-Ex1.54P
KFD0-RO-Ex2
S1SD-1TI-1U
KFD0-CS-Ex1.54P
KFD0-RO-Ex2
KFD0-SCS-1.55
Pepperl+Fuchs Fieldbus Terminator FP-FT-EX1.I.IEC