CATEGORIES
Latest news
- ABB DCS ABB AC 800M ABB CI865 DCS
- ABB DCS ABB AC 800M ABB CI860 DCS
- ABB DCS ABB AC 800M ABB CI857 DCS
- ABB DCS ABB AC 800M ABB CI856 DCS
- ABB DCSABB AC 800M ABB CI853 DCS
Contact us
- ADD: UNIT A1.9/F SILVERCORP INTERNATIONAL TOWER707-713 NATHAN ROAD MONGKOK KOWLOON HONGKONG;
- TEL: 86-027-85508558,86-15871691193
- FAX: 86 027-85309780
- E-mail: sales1@hkxytech.com Jackie@hkxytech.com manager@field-instrument.com
Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B
- Product Model:KFD2-EB2.R4A.B
- Country of origin:Sinapore
- Delivery time:Stock
- Weight:0.5kG
- Product Description: We have good source to supply Pepperl fuchs isolated barrier.If you have any inquiry replate to our scope,pls feel free to contact me
Product introduction
Redundant Power Feed Module KFD2-EB2.R4A.B
Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B
Features• Interface for Power Rail
• Used for redundant configuration
• Supply current ≤ 4 A
• Replaceable fuse
• Relay contact output, reversible
• LED status indication
Function
The power feed module KFD2-EB2.R4A.B interfaces 24 V DC power to the Power Rail at a maximum current of 4 A and is designed for applications requiring redundant power. The twin input terminals allow for daisy-chaining of supply (max. 10 A).
A green LED on the front of the unit indicates that power is on, and a red LED illuminates during error conditions.
In the event of a field wiring or barrier fault from any barrier on the Power Rail, the integral collective error messaging relay alerts the controller via a single digital I/O point. This relay can be configured as normally open or normally closed. Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B
Additionally, the bus implemented in the Power Rail is forwarded to the outside terminals 13 and 15 for usage with KFD2-WAC2-Ex1.D RS 485 connection. Terminal 14 is only for test purposes.Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B
In the sense of functional safety (SIL) the device provides no dangerous failures. Thereby the safe condition of the supplied barrier must be defined as the powerless state. Thus the device will not influence the safety calculation or the SIL value.
This device is compatible with all versions of the Power Rail and provides group fusing.
Note: Redundant systems require two KFD2-EB.R4A.B modules.
Pepperl+Fuchs isolated barrier KFD2-EB2.R4A.B
Detailed Models
P+F KCD2-SCD-1
P+F KCD2-SCD-EX1
P+F KCD2-SR-EX1.LB
P+F KCD2-SR-EX2
P+F KCD2-STC-1
P+F KCD2-STC-EX1
P+F KCD2-STC-EX1.2O
P+F KCD2-UT2-EX1
P+F KFA6-SR2-Ex1.W
P+F KFD0-SD2-Ex1.1045
P+F KFD2-CD2-EX1
P+F KFD2-CRG2-EX1.D
P+F KFD2-DWB-1.D
P+F KFD2-EB2
P+F KFD2-GU-1
P+F KFD2-GUT-Ex1.D
P+F KFD2-SCD2-EX2.LK
P+F KFD2-SH-EX1.T.OP
P+F KFD2-SOT2-Ex2
P+F KFD2-SR2-Ex1.W.LB
P+F KFD2-SR2-Ex2.W
P+F KFD2-ST2-Ex2
P+F KFD2-STC4-1
P+F KFD2-STC4-EX2
P+F KFD2-STC4-Ex2
P+F KFD2-UT2-1
P+F KFD2-UT2-2
P+F KFD2-UT2-EX1
P+F KFD2-UT2-Ex2
P+F KFD2-VR4-EX1.26
KFD2-SR2-Ex2.W
KFD2-SL2-Ex1
KFD2-SR2-Ex1.W
KFD2-STC4-Ex1
KFD2-SR2-EX.1.W.LB
KFD2-EB2.R4A.B
KFD2-SCD2-EX1.LK
KFD2-SR2-EX2.W
KFD2-SL2-EX2.B
KFD0-TT-EX1
KFD0-TR-EX1
KFD2-STC4-EX2
KFD2-UFC-EX1.D
KFD2-SCD2-EX2-LK
KFD2-CD-EX1.32-15
KFD2-STC4-EX1.2O
KFD2-SH-EX1.T.OP
KFD2-SR2-EX2.2S
KFD2-BR-1.PA.93
KFD2-UT2-EX2
KFD2-UFC-EX1.D
KFD0-SD2-EX1.1045
KFD2-SOT2-EX1.LB
KFD2-STC4-EX1.20
KFD2-STC4-1.20,
KFD2-SCD2-EX2.LK
KFD2-SCD2-2.LK
KFD2-SH-EX1
KFD0-SD2-Ex2.1245
KFD2-SL2-Ex1.LK
KFD2-BR-Ex1.3PA.93
KFD2-CD2-EX2
KFD2-UT2-EX2
KFD2-STC4-EX1.2O
KFD2-CR4-1.2O
KFD2-CD2-EX1
KFD2-SL2-EX2
KLD2-PR-1.IEC
KFD2-WAC2-EX1.D
KFD2-UFT-EX2.D
KFD2-UFC-1.D
KFD-STC4-EX1.2O.DE
KFD2-SCD2-EX1
KFD2-PT2-Ex1
KFD2-SR2-EX2.2S
KFD0-SD2-EX1.1045
KCD2-E2L
KCD2-STC-EX1
KFD2-SR2-EX1.W
KFD2-SCD2-EX1-LK
KCD2-SCD-EX1
KFD2-UT2-EX1
KFD2-VR4-EX1.26
KFD2-SR2-EX1.W.LB
KFDO-RSH-1
KFD2-GS-1.2W
KFD2-EB.R4A.B
KFD0-SCS-EX1.55
KFD2-EX1.32
KFD2-STC4-Ex1-Y1.
KFD2-SR2-EX2.2S
KFD2-SCD2-EX2.LK