Yokogawa RAKD42 Variable Area Flowmeter
- Product Model:Yokogawa RAKD42
- Country of origin:Japan
- Delivery time:10 weeks
- Weight:4Kg
- Product Description: We have competitive price and sepecial discount on yokogawa.Pls feel free to send us inquiry to confirm that.
Product introduction
Description
Yokogawa RAKD42 Variable Area Flowmeter
The RAKD Rotameter is used for measurement of liquids and gases and is highly accurate, particularly for low flows and high pressure applications.
The small metal Rotameter RAKD differentiates itself from other comparable variable area meters by means of light and guided float design offering the smallest measurable flow ranges in the market. RAKD meters can be fitted with a fine control valve and are designed with horizontal process connections.
An integrated flow controller based on the differential pressure principle, which allows a constant flow rate to be maintained regardless of any variations in process pressure, is just one of the many different options available. The RAKD with either standard or fail safe limit switches is suitable for safety applications up to SIL level 2. The configuration with valve and controller reaches SIL level 1.
The RAKD Rotameter combines several benefits of the float principle: a robust design, reliable measurements, independence of the electrical power supply when operated as mechanical pointer instruments and an electrical output signal. They are moreover easy to install and require no maintenance. Both the RAMC and the RAKD are packaged in an attractive, all-stainless steel housing and boast a long service life under the harshest industrial conditions.
Yokogawa RAKD Small Metal ROTAMETER
Yokogawa RAKD42 Variable Area Flowmeter
Yokogawa RAKD Small Metal ROTAMETER features include:
Easy-to-read-display
All stainless steel design
Suitable for applications according to IEC 61508 and ISO 13849
Adjustment valve and flow controller available
Fast connection technique using Quickon connector
Intrinsically safe outputs
Special material like Monel and Hastelloy on request
Yokogawa RAKD42 Variable Area Flowmeter
For Pipe Sizes | DN 15 to DN 150 (1/2" – 6") |
Process Connections | Flange, threaded or Triclamp |
Measuring Range |
Water 20°C: 0,1 l/h to 250 l/h Air 20°C 1 bar abs.: 4 l/h to 8000 l/h |
Wetted Parts Material | 1.4571 (AISI 316Ti) Hastelloy, Monel and Titanium on request |
Process Temperature | -25°C to + 250°C |
Process Pressure | 100 bar, higher pressures on request |
Ambient Temperature | -25°C to 100°C |
Accuracy acc. VDE/VDI 3513-2 (qG =50%) | 4 % |
Ex-approvals | ATEX, NEPSI, FM, CSA |
Signal Outputs | Analog 4-20mA, pulse output |
Power Supply | 24 V DC 2-wire |
Degree of Protection | IP66/IP67 |
Suitable for Applications acc. IEC 61508 and Machinery Directive ISO 13849 |
Yes |
Additional Features |
Limit switches for low/high alarms Fine control valves Pressure controller Easy installation with Quickon connector |
FEATURES
• Different process connections like internal threads and flanges
• With fine control valve (horizontal connection) and without valve (vertical connection)
• All wetted parts of stainless steel AISI 316Ti (1.4571) • Measuring accuracy acc. Directive VDI/VDE 3513 sheet 2 (qG=50 %)
• Round industrial standardized stainless steel housing with degree of protection IP 66/67 • Light, guided floats resulting in low pressure loss and stable float movement
• Maximum flow range 1-250 l/h water resp. 40-8000 l/h air, portioned in 13 flow ranges with a relation of 1:10
• Pressure controller (normal up to 25 bar at 20 °C) for a maximum flow of 100 l/h water resp. 3.250 l/h air (only in combination with valve)
• Electronic µP-controlled transmitter with linearized output • Electrical connection by fast connection technique (Quickon)
• Limit switches, also available as “Fail Safe” version
• Connection of common transformer isolated barriers and transmitter power supplies possible
• Intrinsically safe version (Ex-i): ATEX, IECEx, FM, NEPSI, PESO, EAC, INMETRO, KOSHA
• Ex for non- electrical RAKD: ATEX, EAC • FMEDA report available for SIL application
Yokogawa RAKD42 Variable Area Flowmeter
Yokogawa RAKD01 Variable Area Flowmeter
Yokogawa RAKD02 Variable Area Flowmeter
Yokogawa RAKD41 Variable Area Flowmeter
Yokogawa RAKD42 Variable Area Flowmeter
Yokogawa RAKD42 Variable Area Flowmeter
RAKD02-A1SS-41NNN-E80424
RAKD02-A1SS-41NNN-T80NNN
RAKD01-A1SS-41NNN- T80NNN
RAKD01-A2SS-41NNN- T80NNN
RAKD01-D4SS-41NNN- T80NNN
RAKD02-D4SS-41NNN- T80NNN
RAKD02-A2SS-41NNN- T80NNN
RAKD41-T6SS-41VSE-T80NNN
RAKD41-T6SS-43VSE-T80NNN
RAKD41-T6SS-51VSE-T80NNN-K1-KS1
RAKD41-T6SS-41VSE-T80NNN-K1-KS1
RAKD41-T6SS-34VSE-T80NNN-K1-KS1
RAKD41-T6SS-44VSE-T80NNN-K1-KS1
RAMC23-T6SS-61S1 -T90NNN-K1-KS1
RAKD41-T6SS-NNN-T80NNN-K1-KS1
RAKD41-T6SS-43VSE-T80NNN-K1-KS1
RAKD41-T6SS-33VSE- T80NNN-K1-KS1
RAKD41-T6SS-33VSE-T80NNN-K1-KS1
RAKD41-T6SS-43VSE-T80NNN-K1-KS1
RAKD41-T6SS-33VSE-T80NNN-K1-KS1
RAKD41-T6SS-43VSE-T80NNN-K1-KS1
RAKD01-A2SS-31NNN-T80NNN/B1/P6/PP
RAKD01-A2SS-34NNN-E80424 /A29/B1/IE1/KS1/P6/PP
RAKD01-A2SS-31NNN-E80424/A29/B1/IE1/KS1/P6/PP
RAMC02-A2SS-44S0-H90424/A13/B1/IE1/KS1/P3/PP/QK
RAMC04-A2SS-64S2-H90424/A13/B1/IE1/KS1/P3/PP/QK
RAKD01-A2SS-34NNN-E80424/A29/B1/IE1/KS1/P6/PP
RAKD41-T6SS-42NNN-T80NNN/K3/P3
RAKD01-A1SS-41NNN-E80424
RAKD53-W3SS-44VSE-T80NNN/BG/P2/P6/R1
RAKD53-W3SS-44VSE-T80NNN/BG/P2/P6/R1