ABB AX416 Single and dual input analyzers for low level conductivity
Description
Cost effective
ABB AX416 Single and dual input analyzers for low level conductivity
— select one or two conductivity inputs or combine
conductivity and pH/Redox (ORP) in one analyzer
— integral PID controller (AX410)
Reduced installation cost ABB AX416
— easy access terminations; reduced panel space
High functionality at minimum cost
—conductivity, resistivity, difference, ratio, % passage, %
rejection and inferred pH calculations
Expanded monitoring and control
—add-on option board provides a total of five alarm relays
and four ABB AX416 current outputs
—service logbook providing historical data
ABB AX416 Single and dual input analyzers for low level conductivity
Single and Dual Input Analyzers
Both single and dual-input analyzers provide accurate ABB AX416
measurement of low-level conductivity and can be configured
for ranges in µS cm–1, µS m–1, mS cm–1 and mS m–1.
Alternatively, the instrument can be set up for resistivity in
MW-cm, total dissolved solids and salinity.
In addition, the dual-input analyzer calculates, displays and
transmits:ABB AX416
Ratio of Cell 1/Cell 2
Difference Cell 1 – Cell 2
Passage (Cell 1/Cell 2) x 100
Rejection (1 –[Cell 1/Cell 2]) x 100
Inferred pH ABB AX416
These facilities are invaluable tools for demineralization and
reverse osmosis and a host of industrial processes.
ABB AX416 Single and dual input analyzers for low level conductivity
Cation Conductivity and Inferred pH
Measurement
In low conductivity, ABB AX416 ammoniated boiler waters, the AX411
analyzer can calculate an inferred pH measurement from the
conductivity and a preset ammonia concentration. With this
method, one AX411 provides cation conductivity, a direct output
of pH, ABB AX416 reduced cost and none of the maintenance associated
with pH electrodes.
Self-monitoring of the validity of the pH measurement is
achieved by checking that an after-cation conductivity value is
sufficiently low.ABB AX416 This measurement is provided by the second
input of the AX411 analyzer. Alarm contacts can be configured
for cation conductivity, invalid pH and exhausted resin.
ABB AX416 Single and dual input analyzers for low level conductivity
AX41010001
AX41011001
AX41012001
AX41013001
AX41010101
AX41011101
AX41012101
AX41013101
AX41020001
AX41021001
AX41022001
AX41023001
AX41020101
AX41021101
AX41022101
AX41023101
ABB AX416 Single and dual input analyzers for low level conductivity
AX41050001
AX41051001
AX41052001
AX41053001
AX41050101
AX41051101
AX41052101
AX41053101
AX41060001
AX41061001
AX41062001
AX41063001
AX41060101
AX41061101
AX41062101
AX41063101
ABB AX411 Single and dual input analyzers for low level conductivity
AX41070001
AX41071001
AX41072001
AX41073001
AX41070101
AX41071101
AX41072101
AX41073101
Email address:Jackie@hkxytech.com jackie2018@126.com