ABB AX415 Single and dual input analyzers for low level conductivity
Overview
ABB AX415 Single and dual input analyzers for low level conductivity
— select one or two conductivity inputs or combine
conductivity and pH/Redox (ORP) in one analyzer
— integral PID controller (AX410)
Reduced installation cost ABB AX416
— easy access terminations; reduced panel space
High functionality at minimum cost
—conductivity, resistivity, difference, ratio, % passage, %
rejection and inferred pH calculations
Expanded monitoring and control
—add-on option board provides a total of five alarm relays
and four ABB AX416 current outputs
—service logbook providing historical data
ABB AX415 Single and dual input analyzers for low level conductivity
Single and Dual Input Analyzers
Both single and dual-input analyzers provide accurate ABB AX416
measurement of low-level conductivity and can be configured
for ranges in µS cm–1, µS m–1, mS cm–1 and mS m–1.
Alternatively, the instrument can be set up for resistivity in
MW-cm, total dissolved solids and salinity.
In addition, the dual-input analyzer calculates, displays and
transmits:ABB AX416
Ratio of Cell 1/Cell 2
Difference Cell 1 – Cell 2
Passage (Cell 1/Cell 2) x 100
Rejection (1 –[Cell 1/Cell 2]) x 100
Inferred pH ABB AX416
These facilities are invaluable tools for demineralization and
reverse osmosis and a host of industrial processes.
ABB AX415 Single and dual input analyzers for low level conductivity
Cation Conductivity and Inferred pH
Measurement
In low conductivity, ABB AX416 ammoniated boiler waters, the AX411
analyzer can calculate an inferred pH measurement from the
conductivity and a preset ammonia concentration. With this
method, one AX411 provides cation conductivity, a direct output
of pH, ABB AX416 reduced cost and none of the maintenance associated
with pH electrodes.
Self-monitoring of the validity of the pH measurement is
achieved by checking that an after-cation conductivity value is
sufficiently low.ABB AX416 This measurement is provided by the second
input of the AX411 analyzer. Alarm contacts can be configured
for cation conductivity, invalid pH and exhausted resin.
ABB AX415 Single and dual input analyzers for low level conductivity
AX41510001
AX41511001
AX41512001
AX41513001
AX41510101
AX41511101
AX41512101
AX41513101
AX41520001
AX41521001
AX41522001
AX41523001
AX41520101
AX41521101
AX41522101
AX41523101
ABB AX416 Single and dual input analyzers for low level conductivity
AX41550001
AX41551001
AX41552001
AX41553001
AX41550101
AX41551101
AX41552101
AX41553101
AX41560001
AX41561001
AX41562001
AX41563001
AX41560101
AX41561101
AX41562101
AX41563101
ABB AX411 Single and dual input analyzers for low level conductivity
AX41570001
AX41571001
AX41572001
AX41573001
AX41570101
AX41571101
AX41572101
AX41573101
Email address:Jackie@hkxytech.com jackie2018@126.com
Whatsapp:+86 15717178751
Skype:Jackie@hkxytech.com
Telegram:+86 15717178751
Phone:+86 15717178751