ABB AX450 Single and dual input analyzers for low level conductivity
Description
Cost effective
ABB AX450 Single and dual input analyzers for low level conductivity
— select one or two conductivity inputs or combine
conductivity and pH/Redox (ORP) in one analyzer
— integral PID controller (AX410)
Reduced installation cost ABB AX416
— easy access terminations; reduced panel space
High functionality at minimum cost
—conductivity, resistivity, difference, ratio, % passage, %
rejection and inferred pH calculations
Expanded monitoring and control
—add-on option board provides a total of five alarm relays
and four ABB AX416 current outputs ABB AX450
—service logbook providing historical data
ABB AX450 Single and dual input analyzers for low level conductivity
Single and Dual Input Analyzers
Both single and dual-input analyzers provide accurate ABB AX416
measurement of low-level conductivity and can be configured
for ranges in µS cm–1, µS m–1, mS cm–1 and mS m–1.
Alternatively, the instrument can be set up for resistivity in
MW-cm, total dissolved solids and salinity.
In addition, the dual-input analyzer calculates, displays and
transmits:ABB AX416
ABB AX450 Ratio of Cell 1/Cell 2
Difference Cell 1 – Cell 2
Passage (Cell 1/Cell 2) x 100
Rejection (1 –[Cell 1/Cell 2]) x 100
Inferred pH ABB AX416
These facilities are invaluable tools for demineralization and
reverse osmosis and a host of industrial processes.
ABB AX450 Single and dual input analyzers for low level conductivity
Cation Conductivity and Inferred pH
Measurement
In low conductivity, ABB AX416 ammoniated boiler waters, the AX411
analyzer can calculate an inferred pH measurement from the
conductivity and a preset ammonia concentration. With this
ABB AX450 method, one AX411 provides cation conductivity, a direct output
of pH, ABB AX416 reduced cost and none of the maintenance associated
with pH electrodes.
Self-monitoring of the validity of the pH measurement is
achieved by checking that an after-cation conductivity value is
sufficiently low.ABB AX416 This measurement is provided by the second
input of the AX411 analyzer. Alarm contacts can be configured
for cation conductivity, invalid pH and exhausted resin.
ABB AX450 Single and dual input analyzers for low level conductivity
AX45010001
AX45011001
AX45012001
AX45013001
AX45010101
AX45011101
AX45012101
AX45013101
AX45020001
AX45021001
AX45022001
AX45023001
AX45020101
AX45021101
AX45022101
AX45023101
ABB AX450 Single and dual input analyzers for low level conductivity
AX45050001
AX45051001
AX45052001
AX45053001
AX45050101
AX45051101
AX45052101
AX45053101
AX45060001
AX45061001
AX45062001
AX45063001
AX45060101
AX45061101
AX45062101
AX45063101
ABB AX450 Single and dual input analyzers for low level conductivity
AX45070001
AX45071001
AX45072001
AX45073001
AX45070101
AX45071101
AX45072101
AX45073101
Email address:Jackie@hkxytech.com jackie2018@126.com
Whatsapp:+86 15717178751
Skype:Jackie@hkxytech.com
Telegram:+86 15717178751
Phone:+86 15717178751